The SelfCooking Centre 202 Technical
Information
SelfCooking Center®
202 E (20x2/1-40x1/1 GN) |
| Capacity: |
20 x 2/1 GN |
| Lengthwise loading for: |
2/1, 1/1 GN |
| Number of meals per day: |
300-500 |
| Width: |
1.084 mm |
| Depth: |
996 mm |
| Height: |
1.782 mm |
| Minimum distances (left, right, back): |
50 mm |
| Recommended distance for service work
(left): |
500 mm |
| Minimum distance on left for heat
sources: |
350 mm |
| Water supply (pressure hose): |
3/4'' / Ø 1/2'' |
| Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
| Minimum flow rate for filter and soft
water system: |
15,0 l/h |
| Water drain: |
DN 50 mm |
| Connected load: |
62 kW |
| Fuse protection: |
3 x 100 A |
| Mains connection: |
3 NAC 400V |
| "Moist heat" connection: |
54 kW |
| "Dry heat" connection: |
60 kW |
| Weight (net): |
332 kg |
| Cable cross-section: |
5 x 25 mm2 |
| Marks of conformity: |
CE, IPX5, VDE, UL, CUL, NSF, KEMA, PCT,
GS, DVGW, SVGW, WRAS, KIWA |
| Latent heat load: |
12.500 kJ/h |
| Sensitive heat load: |
14.286 kJ/h |
| Required air volume (unit free-standing
in room): |
2.123 m3/h |
| Required air volume (unit with one side
against the wall): |
1.337 m3/h |
| Required air volume (unit with two sides
against the wall): |
849 m3/h |
SelfCooking Center®
202 G (20x2/1-40x1/1 GN) |
| Capacity: |
20 x 2/1 GN |
| Lengthwise loading for: |
2/1, 1/1 GN |
| Number of meals per day: |
300-500 |
| Width: |
1.084 mm |
| Depth: |
996 mm |
| Height: |
1.782 mm |
| Height incl. gas draft diverter: |
2.021 mm |
| Minimum distances (left, right, back): |
50 mm |
| Recommended distance for service work
(left): |
500 mm |
| Minimum distance on left for heat
sources: |
350 mm |
| Water supply (pressure hose): |
3/4'' / Ø 1/2'' |
| Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
| Minimum flow rate for filter and soft
water system: |
15,0 l/h |
| Water drain: |
DN 50 mm |
| Electricity connection: |
1,1 kW |
| Weight (net): |
370,5 kg |
| Fuse protection: |
1 x 16 A |
| Mains connection: |
1 NAC 230 V |
| Cable cross-section |
3 x 2,5 mm2 |
| Gas supply/connection: |
3/4" |
| Connected flow pressure, natural gas H
G20: |
18 - 25 mbar |
| Connected flow pressure, natural gas L
G25: |
20 - 30 mbar |
| Connected flow pressure, liquefied gas
G30: |
25 - 57,5 mbar |
| Connected flow pressure, liquefied gas
G31: |
25 - 57,5 mbar |
| Exhaust gas duct: |
A3 (nur Typ 61), B13, B23 |
| Rated thermal load Liquid gas LPG total: |
67 kW |
| Rated thermal load Liquid gas LPG "Moist
heat": |
53 kW |
| Rated thermal load Liquid gas LPG "Dry
heat": |
67 kW |
| Rated thermal load natural gas total: |
64 kW |
| Rated thermal load natural gas "Moist
heat": |
51 kW |
| Rated thermal load natural gas "Dry
heat": |
64 kW |
| Marks of conformity: |
CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5,
NSF, GASTEC QA, AGA/CSA, JIA, PCT |
| Latent heat load: |
11.583 kJ/h |
| Sensitive heat load: |
13.636 kJ/h |
| Required air volume (unit free-standing
in room): |
2.123 m3/h |
| Required air volume (unit with one side
against the wall): |
1.337 m3/h |
| Required air volume (unit with two sides
against the wall): |
849 m3/h |
|